Heat Sealer Not Sealing? Causes, Checks and the Part to Replace

Stainless steel heat sealing jaw bars on a lab bench beside a clear film pouch

By Alex Hales

When a heat sealer is not sealing, the fault often sits in one of five places. They are the heating element, the PTFE cover or tape over it, the temperature sensor, a loose connection, or weak jaw pressure. On impulse sealers also check the microswitch, timer and rubber backing pad. Start with how the bar behaves, and look at the tape and terminals while you are there.

Each fault leaves a different trace. A bar that never gets hot points one way. A bar that is hot in patches points another, and a bar that reads hot but makes weak seals points a third. A lot of the advice online is written for hand and countertop sealers. This page is for the bar, impulse and jaw sealers on a packaging line, where a wrong guess can stop the line. The setpoint and sensor checks apply to constant-heat bars. Impulse sealers heat in a short pulse, so they get their own checks in the element and tape sections.

Lock it out before you open anything. Isolate the sealer’s electrical supply and its air, and apply your site’s lockout and tagout procedure. OSHA’s lockout standard generally requires it, with narrow exceptions, when servicing a machine that could start up or release stored energy. Heaters stay hot after the power is off, so let the bar cool. Air cylinders can hold pressure and jaws can close on a hand. Resistance checks are done with the power off. Any test on live wiring belongs to a qualified electrician.

Why Is My Heat Sealer Not Sealing?

Start with what the bar is doing. If it stays cold, the fault is in the power path. If it heats unevenly, look at the element, the tape and the jaw face. If it heats fine but the seals are weak, look at the sensor, the pressure and the film.

What you see Likely cause What to check Part to replace
Power light on, bar stays cold Broken element, a loose terminal, or a fuse or relay fault Impulse: look for a broken wire, then terminals and springs. Cartridge: test resistance, then the fuse and relay Heating element, terminal hardware
Slow to heat, or never reaches setpoint Worn element, poor connection, low supply voltage or a failing relay Compare element resistance with its baseline and check the wiring Element, then the relay
Seals on one side only, or in patches Cold spot, debris under the cover or a warped bar Constant-heat bar: map the temperature along its length by the safe method below. Impulse: check the cover, backing pad and element Element, PTFE cover or tape, bar
Film sticks to the bar or the seal looks scorched Worn or burnt PTFE cover Look for tears, bubbles and thin spots PTFE tape or cover
Display shows setpoint, seals still weak Sensor reading drifted from the true bar temperature Constant-heat bar: compare the display with an independent reading, by the safe method below Thermocouple or RTD
Temperature swings up and down Intermittent connection, failing sensor or controller fault Stop the line and diagnose before running more product Sensor, connection, then controller
Seal opens at the same end every time Jaws out of parallel or a worn jaw face With power off and air locked out, check contact with carbon paper, moving the jaws by hand only if that is safe. If the whole seal is weak, check air pressure too Jaw bar, cylinder seals

How Do I Check the Heating Element?

Check the element early, because a bar that shows power and stays cold often has a broken element, though the same symptom can come from a connection or relay. With the machine locked out and cool, look at an exposed element for a break, a bent or discolored section, and any terminal that looks burnt. A cartridge heater cannot be inspected this way, so test its resistance and then check the fuse and relay. Spring hooks and terminals that do not make good contact can also leave the bar cold, and impulse sealer manuals list both among their causes of no seal.

A resistance reading tells you more than a look. One packaging machine heater checklist treats a cold resistance more than 10 percent away from the baseline as a sign of degradation. A baseline means a reading taken when the element was new. If you have never recorded one, write it down on the next element you fit, and use the maker’s rated resistance in the meantime.

On an impulse sealer, replace the bottom PTFE strip every time you replace the element. Sealer Sales’ troubleshooting notes link a burnt-through bottom strip to elements that break and arc to the body, so a new element on an old strip can fail the same way.

Is the PTFE Tape or Cover Worn?

Yes if the film sticks to the bar, the cover looks brown or thin, or you see tears and bubbles. Worn PTFE lets the film touch bare metal, which makes it stick and leaves a weak or scorched seal. With the bar locked out and cool, looking at the tape is a quick check, so do it early.

Tape width, thickness and adhesive all matter when you reorder, and our guide to Teflon tape for heat sealers covers how to measure and apply it. Debris under the tape is one cause of uneven seal quality, so clean the bar face fully when you re-tape.

Why Does My Heat Sealer Seal on One Side Only?

One-sided or patchy sealing means the heat or the pressure is uneven along the bar. The heater checklist lists a partly burnt element with a cold zone, debris under the PTFE and a warped bar. Jaws out of parallel do the same. The checklist suggests mapping temperature across the seal surface.

On a constant-heat bar only, readings at several points along the bar with a contact thermometer will show a cold zone. This is a live check, so follow your site’s procedure for testing under 29 CFR 1910.147(f). Isolate and lock the air, block the jaws open mechanically, keep hands clear of the hot face, and use a long-handled probe once the bar has settled at setpoint. If you cannot do that, peel a few finished seals apart and look for one side that is weaker, which needs no heat. Impulse elements only heat in a pulse, so this reading does not apply to them. The checklist flags a spread of more than 10 degrees F across the bar as a reason to investigate. Treat that as a prompt to look closer rather than a pass mark, because the right spread depends on your film and your machine.

If the heat is even and the seal still opens at one end, suspect pressure. A worn jaw face or a bar that has lost its flatness presses unevenly. Our jaw bar replacement guide lists the wear signs. On Hayssen jaws, replacing only the worn half is fine as long as the other half still measures flat and shows no pitting.

Can the Temperature Display Be Wrong?

Yes, and it is one of the easiest faults to miss. A sensor sits at one spot in the jaw, so if it drifts the display can look fine while the film runs cooler. The heater checklist suggests investigating when the display and an independent reading differ by more than 5 degrees F.

Check that the sensor is seated against the bar, that its wire is not damaged, and that its reading matches an independent reading taken the same safe way as above, on a constant-heat bar. A sensor that has failed open can show up as a controller fault code, so read the controller manual before you replace anything. Our sealing jaw parameters guide explains why the displayed temperature is not the film temperature and how coating wear shifts it.

Could It Be Pressure, Dwell Time or the Film?

Yes, if the heat path checks out. Low air pressure, a worn cylinder seal, a dwell time shortened to gain speed, or a change of film can each give a weak seal on a sealer that is working properly. Settings that suit one film can fail on another, so use the film maker’s seal range and the machine maker’s spec, not a number copied from another line.

After any repair, prove the fix with a test and not by eye. A seal can look right and still peel or leak. Our seal strength testing guide covers peel, burst and leak tests, and the heat sealing maintenance guide covers the checks that catch these faults before they stop the line.

Which Part Do I Replace and How Do I Match It?

Replace the part the checks pointed to, and order it with the details that stop a near match. A heating element or cartridge heater has to match in length, voltage and wattage (plus ribbon width and thickness on impulse elements), and a thermocouple has to match in type and length. Tape has to match in width and thickness.

1
Read the old part
Copy any number, voltage and wattage stamped on the old element, heater or sensor, and photograph how it is mounted before you remove it.
2
Measure what is left
Record element or bar length, tape width and thickness, and the sensor type and probe length. Use the same unit for every number.
3
Note the machine
Write down the maker, model and which station the part sits in, plus the film you run.
4
Send it all together
Send the numbers, the measurements and the photos in one message so the supplier can confirm the match.

Vanguard’s heat sealing parts category lists heating elements, cartridge heaters, thermocouples, PTFE tape, jaw bars and seal profiles. The page says custom parts can be supplied from a drawing, an OEM part number or a physical sample, which helps when the original part is no longer available. Send your part details through the quote form on that page.

Frequently Asked Questions

Latest Blogs

Pneumatic cylinder with a blank label beside digital calipers and an O-ring on a white lab bench

Replacement Part With No Part Number? How to Find the Match

White packaging conveyor belt with stainless steel side guides carrying cartons

Packaging Conveyor Belt Problems: Mistracking, Slipping and Fraying Fixed in Order

Vertical form fill seal machine with forming tube, sealing jaws and a filled clear bag

VFFS Seal Problems: Leaks, Wrinkles and Burn-Through, and What to Fix First

Contact Us

or

Get a quote

Get a quote